Series |
Case Size |
Input Range |
Input Voltage (VAC) |
Output Voltage (VAC) |
Isolation (kVAC) |
Regulation |
SCP * |
η max. |
Operating Temp. |
PFC |
Parallel |
Certs |
||
![]() | 15ACDRSS_4 | 90.00 x 58.00 x 18.00mm | wide | 85-264VAC; 120-370Vdc; 47-63Hz | 5; 12; 15; 24; 48 | 4 | • | • | 90% | -40°C ~ +70°C | UL62368 |
Series |
Case Size |
Input Range |
Input Voltage (VAC) |
Output Voltage (VAC) |
Isolation (kVAC) |
Regulation |
SCP * |
η max. |
Operating Temp. |
PFC |
Parallel |
Certs |
||
![]() | 30ACDRSS_4 | 90.00 x 58.00 x 35.00mm | wide | 85-264VAC; 120-370Vdc; 47-63Hz | 5; 12; 15; 24; 48 | 4 | • | • | 90% | -40°C ~ +70°C | UL62368 |
Series |
Case Size |
Input Range |
Input Voltage (VAC) |
Output Voltage (VAC) |
Isolation (kVAC) |
Regulation |
SCP * |
η max. |
Operating Temp. |
PFC |
Parallel |
Certs |
||
![]() | 60ACDRSS_4 | 90.00 x 58.00 x 52.00mm | wide | 85-264VAC; 120-370Vdc; 47-63Hz | 5; 12; 15; 24; 48 | 4 | • | • | 91% | -40°C ~ +70°C | UL62368 |
Series |
Case Size |
Input Range |
Input Voltage (VAC) |
Output Voltage (VAC) |
Isolation (kVAC) |
Regulation |
SCP * |
η max. |
Operating Temp. |
PFC |
Parallel |
Certs |
||
![]() | 75ACDR1_SC3 | 125.00 x 113 x 42.00mm | wide | 90-264VAC; 47-63Hz | 3 | 3 | • | • | 86% | -30°C ~ +70°C | UL62368 |
Series |
Case Size |
Input Range |
Input Voltage (VAC) |
Output Voltage (VAC) |
Isolation (kVAC) |
Regulation |
SCP * |
η max. |
Operating Temp. |
PFC |
Parallel |
Certs |
||
![]() | 100ACDRSS_4 | 90.00 x 70.02 x 58.40mm | wide | 90-264VAC; 127-370Vdc; 47-63Hz | 12; 15; 24; 48 | 4 | • | • | 90% | -20°C ~ +70°C | UL62368 |
Series |
Case Size |
Input Range |
Input Voltage (VAC) |
Output Voltage (VAC) |
Isolation (kVAC) |
Regulation |
SCP * |
η max. |
Operating Temp. |
PFC |
Parallel |
Certs |
||
![]() | 120ACDR1_SC3 | 125 x 113 x 42mm | wide | 85-264VAC; 120-370Vdc; 47-63Hz | 12; 24; 48 | 4 | • | • | 88% | -40°C ~ +70°C | • | UL62368 UL61010 |
Series |
Case Size |
Input Range |
Input Voltage (VAC) |
Output Voltage (VAC) |
Isolation (kVAC) |
Regulation |
SCP * |
η max. |
Operating Temp. |
PFC |
Parallel |
Certs |
||
![]() | 150ACDRSS_4 | 90.00 x 58.00 x 105.00mm | wide | 90-264VAC; 127-370Vdc; 47-63Hz | 12; 15; 24; 48 | 4 | • | • | 91% | -30°C ~ +70°C | • | EN62368 |
Series |
Case Size |
Input Range |
Input Voltage (VAC) |
Output Voltage (VAC) |
Isolation (kVAC) |
Regulation |
SCP * |
η max. |
Operating Temp. |
PFC |
Parallel |
Certs |
||
![]() | 240ACDR1_SC3 | 125 x 113 x 63mm | wide | 85-264VAC; 120-370Vdc; 47-63Hz | 24; 48 | 3 | • | • | 89% | -30°C ~ +70°C | • | UL62368 |
Series |
Case Size |
Input Range |
Input Voltage (VAC) |
Output Voltage (VAC) |
Isolation (kVAC) |
Regulation |
SCP * |
η max. |
Operating Temp. |
PFC |
Parallel |
Certs |
||
![]() | 480ACDR1_SC3 | 130.60 x 131.50 x 48.00mm | wide | 85-264VAC; 120-370Vdc; 47-63Hz | 24; 48 | 3 | • | • | 94,5% | -40°C ~ +70°C | • | UL62368 UL61010 |
Series |
Case Size |
Input Range |
Input Voltage (VAC) |
Output Voltage (VAC) |
Isolation (kVAC) |
Regulation |
SCP * |
η max. |
Operating Temp. |
PFC |
Parallel |
Certs |
||
![]() | 960ACDRP_C3 | 125.2 x 150.0 x 110.00mm | wide | 180-264VAC; 254-370Vdc; 47-63Hz | 24; 48 | 3 | • | • | 94,4% | -30°C ~ +70°C | • | UL-508 |