• Skip to main content

Gaptec Electronic GmbH

Innovative Designs - Premium Quality - Micro Size Converters - Custom Design - Certified Manufacturing

  • Home
  • Products
    • Selection-Guide-2022
    • E-Mobility
    • Power-Chart Overview
    • Railway Application Scheme
    • AC-DC Modules (Industrial)
    • AC-DC Modules (Medical)
    • AC-DC Power Supply (Medical)
    • AC DC DIN Rail (Industrial)
    • AC-DC Off Board (Housing)
    • AC-DC Off Board (Open Frame)
    • DC-DC Converters (Industrial)
    • DC-DC Converters (Railway)
    • DC-DC Converters (Telecom)
    • DC-DC Converters (IGBT & SiC)
    • DC-DC Converters (Photovoltaic)
    • DC-DC Converters (POL)
    • DC-DC Converters (LED Drivers)
  • Isolation Calculator
  • About us
  • Info
  • Application Notes
    • Video: Linear Regulators
      vs. Switching Regulators
    • AC-DC
      Application Notes
    • Fixed Input (DC-DC)
      Application Notes
    • Wide Input (DC-DC)
      Application Notes
    • Railway (DC-DC)
      Application Notes
    • IGBT (DC-DC)
      Application Notes
    • Photovoltaic (DC-DC)
      Application Notes
    • Non-Isolated Switching Regulator
      Application Notes
    • LED (DC-DC)
      Application Notes
  • Components
  • 3D CAD
  • ECAD
  • Press Releases
  • Contact
  • English
  • German

Product Filter:
AC-DC Converters

Reset Back

Package

All
Modules
Modules Open Frame
Power Supplies Housing
Power Supplies Open Frame
Power Supplies U-Bracket
Power Supplies Din-Rail

Input Voltage Range

All
up to 264VAC
up to 305VAC
up to 400VAC
up to 430VAC
up to 528VAC
up to 745VAC

Isolation

All
≥ 3 kV
≥ 4 kV

Application

All
Industrial
Medical

Input Voltage Type

All
VAC
VAC & VDC

Output

All
Single
Dual

Cert Type

All
UL-60950
UL-62368
UL-60601

Options

Active PFC
Support 1+1/N+1
FAN
2 x MOPP
* SCP: Short Circuit Protection

0 watt 1 watt 2 watts 3 watts 4 watts 5 watts 8 watts 10 watts 12 watts 15 watts 20 watts 25 watts 30 watts 35 watts 40 watts 45 watts 50 watts 60 watts 65 watts 75 watts 100 watts 120 watts 125 watts 150 watts 180 watts 200 watts 240 watts 280 watts 320 watts 360 watts 480 watts 500 watts 600 watts 960 watts
 
1 Watt AC -DC converter
 

Series

Case Size

Input Range

Input Voltage (VDC)

Output Voltage (VDC)

Isolation (kVDC)

Regulation

SCP *

η max.

Operation Temp.

Certs

1ACOS_SSIP open framewide85-305VAC; 47-63Hz; 70-430VDC5Non-isolated••57%-40°C - +85°CUL62368

 
2 Watt AC -DC converter
 

Series

Case Size

Input Range

Input Voltage (VDC)

Output Voltage (VDC)

Isolation (kVDC)

Regulation

SCP *

η max.

Operation Temp.

Certs

2ACEW_4DIP 33.7 x 22.2 mmwide85-305VAC; 47-63Hz; 120-430VDC3.3; 5; 9; 12; 15; 24478%-40°C - +70°CUL62368

 
3 Watt AC -DC converter
 

Series

Case Size

Input Range

Input Voltage (VDC)

Output Voltage (VDC)

Isolation (kVDC)

Regulation

SCP *

η max.

Operation Temp.

Certs

3ACOS_SSIP open framewide85-305VAC; 47-63Hz; 70-430VDC12Non-isolated••57%-40°C - +85°CUL62368
3ACFEW_3SIP open framewide85-305VAC; 47-63Hz; 70-430VDC3.3; 5; 9; 12; 15; 243••80%-40°C - +85°CUL62368
3ACA_3RDIP 37 x 23 mmwide85-264VAC; 47-63Hz; 120-370VDC3.3; 5; 9; 12; 15; 243••78%-40°C - +85°CUL62368
3ACEW_4DIP 1"x 1"wide85-305VAC; 47-63Hz; 100-430VDC3.3; 5; 9; 12; 15; 244••79%-40°C - +85°CUL62368
3ACMW_4SIP open framewide90-528VAC; 47-63Hz; 100-745VDC3.3; 5; 9; 12; 15; 244••76%-40°C - +85°CUL60950
3ACE_4DIP 37 x 24.5 mm85-264VAC; 47-63Hz; 120-370VDC3.3; 5; 9; 12; 15; 244••73%-40°C - +70°CUL62368

 
5 Watt AC -DC converter
 

Series

Case Size

Input Range

Input Voltage (VDC)

Output Voltage (VDC)

Isolation (kVDC)

Regulation

SCP *

η max.

Operation Temp.

Certs

5ACDM_3DIP 1“ x 1“wide90-264VAC; 47-63Hz; 120-370VDC3.3; 5; 9; 12; 15; 24; 483••85%-40°C - +70°CUL62368
5ACE_4DIP 37 x 24.5 mmwide90-264VAC; 47-63Hz; 120-370VDC3.3; 5; 9; 12; 15; 244••81%-40°C - +70°CUL62368
5ACMEA_4DIP 52.5 x 27.5 mm wide90-264VAC; 47-63Hz; 120-370VDC5, 9; 12; 15; 244••85%-40°C - +80°CUL60950
5ACAW_4DIP 53.8 x 28.8 mmwide85-305VAC; 47-63Hz; 120-430VDC3.3; 5; 9; 12; 15; 244•80%-40°C - +70°CUL60950
5ACBE_4DIP 48.5 x 36 mmwide85-264VAC; 47-63Hz; 120-370VDC3.3; 5; 9; 12; 15; 244••82%-40°C - +85°CUL62368
5ACM_4SIP14 open framewide85-264VAC; 47-63Hz; 70-400VDC3.3; 5; 9; 12; 15; 244••79%-40°C - +85°CUL62368
5ACEW_4DIP 1“ x 1“wide85-305VAC; 47-63Hz; 100-430VDC3.3; 5; 9; 12; 15; 244••81,5-40°C - +85°CUL62368
5ACFEW_3SIP open framewide85-305VAC; 47-63Hz; 70-430VDC3.3; 5; 9; 12; 15; 243••81%-40°C - +85°CUL62368

 
10 Watt AC -DC converter
 

Series

Case Size

Input Range

Input Voltage (VDC)

Output Voltage (VDC)

Isolation (kVDC)

Regulation

SCP *

η max.

Operation Temp.

Certs

10ACFEW_3SIP open framewide85-305VAC; 47-63Hz; 70-430VDC3.3; 5; 9; 12; 15; 243••81%-40°C - +85°CUL62368
10ACBE_4DIP 55 x 45 mmwide85-264VAC; 47-63Hz; 120-370VDC3.3; 5; 9; 12; 15; 244••82%-40°C - +85°CUL62368
10ACBEW_4DIP 55 x 45 mmwide85-305VAC; 47-63Hz; 100-430VDC3.3; 5; 9; 12; 15; 244••82%-40°C - +85°CUL62368
10ACE_4DIP 53.8 x 28.8 mmwide85-264VAC; 47-63Hz; 120-370VDC3.3; 5; 9; 12; 15; 244••83%-40°C - +85°CUL62368
10ACEW_4DIP 40 x 25.4 mmwide85-305VAC; 47-63Hz; 100-430VDC3.3; 5; 9; 12; 15; 244••85%-40°C - +85°CUL62368
10ACM_3SIP14 open framewide85-305VAC; 47-63Hz; 100-430VDC3.3; 5; 9; 12; 15; 243••82%-40°C - +85°CUL62368

 
15 Watt AC -DC converter
 

Series

Case Size

Input Range

Input Voltage (VDC)

Output Voltage (VDC)

Isolation (kVDC)

Regulation

SCP *

η max.

Operation Temp.

Certs

15ACP_S79 x 51 x 28.8mmwide90-264VAC; 47-63Hz3.3; 5; 12; 15; 243••83%-25°C ~ 70°CUL60950
15ACEW_4DIP 47,5 x 26,8mmwide85-305VAC; 47-63Hz; 100-430VDC3.3; 5; 9; 12; 15; 244••86%-40°C - +85°CUL62368
15ACBE_4DIP 62,0 x 45,0mmwide85-264VAC; 47-63Hz; 100-370VDC3.3; 5; 9; 12; 15; 24; ±5; ±12; ±154••83%-40°C - +85°CUL62368
15ACE_4DIP 53,8 x 28,8mmwide85-264VAC; 47-63Hz; 100-370VDC3.3; 5; 9; 12; 15; 244••81%-40°C - +70°CUL62368
15ACM_3SIP open-framewide85-305VAC; 47-63Hz; 100-430VDC3.3; 5; 9; 12; 15; 243••85%-40°C - +85°CUL62368
15ACBEW_4DIP 62,0 x 45,0mmwide85-305VAC; 47-63Hz; 100-430VDC3.3; 5; 9; 12; 15; 24; 484••85%-40°C - +85°CUL62368
15ACMEB_4DIP 62,0 x 45,0mmwide85-264VAC; 47-63Hz; 120-370VDC5; 12; 15; 18; 244••86%-40°C - +85°CUL60601

 
20 Watt AC -DC converter
 

Series

Case Size

Input Range

Input Voltage (VDC)

Output Voltage (VDC)

Isolation (kVDC)

Regulation

SCP *

η max.

Operation Temp.

Certs

20ACPO_S89 x 51 x 20 mmwide85-264VAC; 47-63Hz; 120-370VDC3.3; 5; 12; 15; 24; 483••80%-25°C ~ 70°CUL60950
20ACE_4DIP 52.5 x 27.5 mmwide90-264VAC; 47-63Hz; 120-370VDC3.3; 5; 12; 15; 244••83%-40°C - +70°CUL62368
20ACEW_4DIP 52.4 x 27.2 mm wide85-305VAC; 47-63Hz; 100-430VDC3.3; 5; 9; 12; 15; 244••87%-40°C - +85°CUL62368

 
25 Watt AC -DC converter
 

Series

Case Size

Input Range

Input Voltage (VDC)

Output Voltage (VDC)

Isolation (kVDC)

Regulation

SCP *

η max.

Operation Temp.

Certs

25ACP_S79 x 51 x 28.8mmwide90-264VAC; 47-63Hz3.3; 5; 12; 15; 243••84%-25°C ~ 70°CUL60950
25ACBE_4DIP 70.0 x 48.0mm85-305VAC; 47-63Hz; 100-430VDC3.3; 5; 9; 12; 15; 24; 484••87%-40°C - +85°CUL62368
25ACBEW_4DIP 70.0 x 48.0mm85-305VAC; 47-63Hz; 100-430VDC3.3; 5; 9; 12; 15; 24; 484••87%-40°C - +85°CUL62368

 
30 Watt AC -DC converter
 

Series

Case Size

Input Range

Input Voltage (VDC)

Output Voltage (VDC)

Isolation (kVDC)

Regulation

SCP *

η max.

Operation Temp.

Certs

30ACDRS_S92.66 x 58.00 x 35.00mmwide85-264VAC; 120-370Vdc; 47-63Hz5; 12; 15; 24; 484••90%-40°C ~ +70°CUL62368
30ACMEB_4DIP 61.1 x 45.6 mm wide85-264VAC; 47-63Hz; 120-370VDC5; 12; 15; 244••89%-40°C - +80°CUL60601

 
35 Watt AC -DC converter
 

Series

Case Size

Input Range

Input Voltage (VDC)

Output Voltage (VDC)

Isolation (kVDC)

Regulation

SCP *

η max.

Operation Temp.

Certs

35ACP_S101.6 x 63.5 x 33mmwide90-264VAC; 47-63Hz; 127-370VDC5; 12; 15; 24; 483••88%-25°C ~ 70°CUL60950
35ACPO_S101,6 x 51 x 24 mmwide90-264VAC; 47-63Hz5; 12; 24; 483••86%-20°C ~ 65°CUL60950

 
45 Watt AC -DC converter
 

Series

Case Size

Input Range

Input Voltage (VDC)

Output Voltage (VDC)

Isolation (kVDC)

Regulation

SCP *

η max.

Operation Temp.

Certs

45ACPO_S101,6 x 51 x 28 mmwide90-264VAC; 47-63Hz12; 24; 483••86%-10°C ~ 60°CUL60950

 
50 Watt AC -DC converter
 

Series

Case Size

Input Range

Input Voltage (VDC)

Output Voltage (VDC)

Isolation (kVDC)

Regulation

SCP *

η max.

Operation Temp.

Certs

50ACP_S99 x 82 x 35mmwide88-264VAC; 47-63Hz; 127-370VDC5; 12; 15; 24; 483••88,5%-25°C ~ 70°CUL60950

 
60 Watt AC -DC converter
 

Series

Case Size

Input Range

Input Voltage (VDC)

Output Voltage (VDC)

Isolation (kVDC)

Regulation

SCP *

η max.

Operation Temp.

Certs

60ACDRS_S92.66 x 58.00 x 52.00mm85-264VAC; 120-370Vdc; 47-63Hz5; 12; 15; 24; 484••91%-40°C ~ +70°CUL62368
60ACPO_S101,6 x 50,8 x 30 mmwide90-264VAC; 47-63Hz5; 12; 15; 24; 483••87%-25°C ~ 70°CUL60950
60ACPO_SE101,6 x 51 x 29 mmwide90-264VAC; 47-63Hz5; 12; 15; 24; 483••86%-10°C ~ 65°CUL60950
60ACBE_4DIP 96,32 x 58,50mmwide85-264VAC; 47-63Hz; 100-370VDC5; 12; 15; 24; 484••86%-40°C - +70°CUL62368
60ACMEB_489.0 x 63.5 x 27.0 mmwide90-264VAC; 47-63Hz; 120-370VDC5; 9; 12; 15; 244••87%-40°C - +70°CUL60601

 
65 Watt AC -DC converter
 

Series

Case Size

Input Range

Input Voltage (VDC)

Output Voltage (VDC)

Isolation (kVDC)

Regulation

SCP *

η max.

Operation Temp.

Certs

65ACMOP76,2 x 50,8 x 28,7 mmwide90-264VAC; 47-63Hz5, 12, 15, 19, 20, 24, 28,48, 564••87%-20°C - +70°CUL60601

 
75 Watt AC -DC converter
 

Series

Case Size

Input Range

Input Voltage (VDC)

Output Voltage (VDC)

Isolation (kVDC)

Regulation

SCP *

η max.

Operation Temp.

Certs

75ACDRH_S129.80 x 87.50 x 32.00mmwide85-264VAC; 120-370Vdc; 47-63Hz12; 24; 484••90%-30°C ~ +70°CUL61010
75ACP_S129 x 98 x 38mmwide90-264VAC; 47-63Hz5; 12; 15; 24; 483••88%-25°C ~ 70°CUL60950

 
100 Watt AC -DC converter
 

Series

Case Size

Input Range

Input Voltage (VDC)

Output Voltage (VDC)

Isolation (kVDC)

Regulation

SCP *

η max.

Operation Temp.

Certs

100ACDRS_S92.66 x 58.00 x 70.00mmwide85-264VAC; 120-370Vdc; 47-63Hz12; 15; 24; 484••90%-40°C ~ +70°CUL62368
100ACP_SC199 x 99 x 38mmwide85-264VAC; 47-63Hz12; 24; 36; 483••87%-20°C ~ 65°CUL60950
100ACPM_SC129 x 98,3 x 37,6mmwide90-264VAC; 47-63Hz5; 12; 24; 483••88%-20°C ~ 60°CUL60950
100ACMEA_4109.0 x 58.8 x 35.9 mmwide90-264VAC; 47-63Hz12; 15; 24; 484••93.50%-30°C - +70°CUL60601
100ACMEB_483.9 x 58.8 x 35.0 mmwide90-264VAC; 47-63Hz12, 24, 484••90%-30°C - +70°CUL60601

 
120 Watt AC -DC converter
 

Series

Case Size

Input Range

Input Voltage (VDC)

Output Voltage (VDC)

Isolation (kVDC)

Regulation

SCP *

η max.

Operation Temp.

Certs

120ACDRH_SC128.82 x 110.00 x 32.00mmwide85-264VAC; 120-370Vdc; 47-63Hz12; 24; 484••94%-40°C ~ +70°CUL62368 UL61010

 
125 Watt AC -DC converter
 

Series

Case Size

Input Range

Input Voltage (VDC)

Output Voltage (VDC)

Isolation (kVDC)

Regulation

SCP *

η max.

Operation Temp.

Certs

125ACPO_SP127 x 76 x 30,5mmwide90-264VAC; 47-63Hz; 127-370VDC5; 12; 15; 24; 36; 483••87%-20°C ~ 70°C

 
150 Watt AC -DC converter
 

Series

Case Size

Input Range

Input Voltage (VDC)

Output Voltage (VDC)

Isolation (kVDC)

Regulation

SCP *

η max.

Operation Temp.

Certs

150ACPEW_S4
150ACDR_S89.12 x 58.00 x 105.00mmwide85-264VAC; 120-370Vdc; 47-63Hz12; 15; 24; 484••91%-30°C ~ +70°CEN62368
150ACP_S199 x 98.3 x 38mmwide90-132VAC & 176-264VAC; 47-63Hz12; 24 3••87%-20°C ~ +65°CUL60950
150ACP_SC199 x 99 x 38mmwide85-264VAC; 47-63Hz12; 24; 27.6; 483••87%-20°C ~ +65°CUL60950
150ACPM_SC160 x 99 x 38mmwide90-264VAC; 47-63Hz; 120 – 370Vdc12; 15; 24; 483••88%-20°C ~ 70°CUL60950
150ACMEA_4109.0 x 58.8 x 35.9 mmwide85-264VAC; 47-63Hz12; 15; 24; 484••93.50%-30°C - +70°CUL60601

 
180 Watt AC -DC converter
 

Series

Case Size

Input Range

Input Voltage (VDC)

Output Voltage (VDC)

Isolation (kVDC)

Regulation

SCP *

η max.

Operation Temp.

Certs

180ACMOP127 x 76,2 x 30 mmwide90-264VAC; 47-63Hz 12, 15, 19, 24, 28, 484••87%0°C - +60°CUL60601

 
200 Watt AC -DC converter
 

Series

Case Size

Input Range

Input Voltage (VDC)

Output Voltage (VDC)

Isolation (kVDC)

Regulation

SCP *

η max.

Operation Temp.

Certs

200ACMUP176 x 95 x 50 mmwide90-264VAC; 47-63Hz 12, 16, 19, 20, 24, 36, 484••87%0°C - +60°CUL60601
200ACP_SC199 x 99 x 38mmwide90-264VAC; 47-63Hz12; 15; 483••88,5%-20°C ~ +65°CUL60950
200ACP_SCF199 x 99 x 50mmwide90-264VAC; 47-63Hz; 120 – 370Vdc12; 24; 36; 483••87%-20°C ~ +65°CUL60950
200ACPO_SP128 x 76,5 x 34,6mmwide90-264VAC; 47-63Hz; 127 – 370Vdc12; 24; 483••90%-20°C ~ +70°CUL60950

 
240 Watt AC -DC converter
 

Series

Case Size

Input Range

Input Voltage (VDC)

Output Voltage (VDC)

Isolation (kVDC)

Regulation

SCP *

η max.

Operation Temp.

Certs

240ACDRH_SC128.00 x 110.00 x 54.00mmwide85-264VAC; 120-370Vdc; 47-63Hz12; 24; 483••94%-40°C ~ +70°CUL62368 UL61010

 
280 Watt AC -DC converter
 

Series

Case Size

Input Range

Input Voltage (VDC)

Output Voltage (VDC)

Isolation (kVDC)

Regulation

SCP *

η max.

Operation Temp.

Certs

280ACMOP127 x 76,2 x 30 mmwide90-264VAC; 47-63Hz12, 24, 28, 36, 48, 544••91%-20°C - +70°CUL60601
280ACMUP127 x 83,2 x 38 mmwide90-264VAC; 47-63Hz12, 24, 28, 36, 48, 544••91%-20°C - +70°CUL60601
280ACMHP127 x 83,2 x 39,5 mmwide90-264VAC; 47-63Hz12, 24, 28, 36, 48, 544••91%-20°C - +70°CUL60601

 
320 Watt AC -DC converter
 

Series

Case Size

Input Range

Input Voltage (VDC)

Output Voltage (VDC)

Isolation (kVDC)

Regulation

SCP *

η max.

Operation Temp.

Certs

320ACP_SCF199 x 99 x 50mmwide90-264VAC; 47-63Hz; 120 – 370Vdc12; 24; 36; 483••87,5%-20°C ~ +65°CUL60950

 
360 Watt AC -DC converter
 

Series

Case Size

Input Range

Input Voltage (VDC)

Output Voltage (VDC)

Isolation (kVDC)

Regulation

SCP *

η max.

Operation Temp.

Certs

360ACMOP152,4 x 101,6 x 30 mmwide90-264VAC; 47-63Hz12, 24, 28, 48, 544••90%-0°C - +70°CUL60601
360ACMUP203,2 x 118,5 x 42 mmwide90-264VAC; 47-63Hz12, 24, 30, 36, 48, 54, 574••83%-0°C - +70°CUL60601

 
480 Watt AC -DC converter
 

Series

Case Size

Input Range

Input Voltage (VDC)

Output Voltage (VDC)

Isolation (kVDC)

Regulation

SCP *

η max.

Operation Temp.

Certs

480ACDRH_SC130.60 x 131.50 x 48.00mmwide85-264VAC; 120-370Vdc; 47-63Hz12; 24; 483••94%-40°C ~ +70°CUL62368 UL61010
480ACDR_SC127 x 124 x 70mmwide85-264VAC; 130-350Vdc; 47-63Hz24; 483••93,8%-25°C ~ +70°CUL60950

 
500 Watt AC -DC converter
 

Series

Case Size

Input Range

Input Voltage (VDC)

Output Voltage (VDC)

Isolation (kVDC)

Regulation

SCP *

η max.

Operation Temp.

Certs

500ACMUP203,2 x 118,5 x 42 mmwide90-264VAC; 47-63Hz12, 24, 30, 36, 48, 54, 574••83%-0°C - +70°CUL60601

 
600 Watt AC -DC converter
 

Series

Case Size

Input Range

Input Voltage (VDC)

Output Voltage (VDC)

Isolation (kVDC)

Regulation

SCP *

η max.

Operation Temp.

Certs

600ACP_SCF218 x 116,5 x 40,7mmwide90-264VAC; 47-63Hz12; 24; 483••93,8%-20°C ~ +70°CUL60950
600ACP_SCTF218 x 116,5 x 41mmwide90-264VAC; 47-63Hz; 127-370VDC12; 24; 27; 36; 483••90.00%-30°C ~ +70°CUL60950

 
960 Watt AC -DC converter
 

Series

Case Size

Input Range

Input Voltage (VDC)

Output Voltage (VDC)

Isolation (kVDC)

Regulation

SCP *

η max.

Operation Temp.

Certs

960ACDR_SC138.2 x 124.6 x 140mmwide85-264VAC; 220-370Vdc; 47-63Hz243••94,4%-25°C ~ +70°C

  • Imprint
  • Disclaimer/Privacy Policy
  • Terms & Conditions

© 2023 GAPTEC Electronic, All Rights Reserved.

  • Home
  • Products
    ▼
    • Power-Chart Overview
    • AC-DC Modules (Industrial)
    • AC-DC Modules (Medical)
    • AC-DC Power Supply Medical
    • AC DC DIN Rail
    • AC-DC Off Board (Housing)
    • AC-DC Off Board (Open Frame)
    • DC-DC Converters (Industrial)
    • DC-DC Converters (Railway)
    • DC-DC Converters (Telecom Power)
    • DC-DC Converters (IGBT & SiC)
    • DC-DC Converters (Photovoltaic)
    • DC-DC Converters (POL)
    • DC-DC Converters (PoE)
    • DC-DC Converters (LED Drivers)
  • Isolation Calculator
  • About us
  • Info
  • Application Notes
    ▼
    • Video: Linear Regulators
      vs. Switching Regulators
    • AC-DC
      Application Notes
    • Fixed Input (DC-DC)
      Application Notes
    • Wide Input (DC-DC)
      Application Notes
    • Railway (DC-DC)
      Application Notes
    • IGBT (DC-DC)
      Application Notes
    • Photovoltaic (DC-DC)
      Application Notes
    • Non-Isolated Switching Regulator
      Application Notes
    • LED (DC-DC)
      Application Notes
  • Approvals & Certifications
  • Components Service
  • Press Releases
  • Contact
  • 3D CAD
  • English
    ▼
    • Deutsch
We use cookies on our website to give you the most relevant experience by remembering your preferences and repeat visits. By clicking “Accept”, you consent to the use of ALL the cookies. However you may visit Cookie Settings to provide a controlled consent.
Cookie settingsAccept
Privacy & Cookies Policy

Privacy Preference Centre

When you visit any web site, it may store or retrieve information on your browser, mostly in the form of cookies. This information might be about you, your preferences or your device and is mostly used to make the site work as you expect it to. The information does not usually directly identify you, but it can give you a more personalised web experience. Because we respect your right to privacy, you can choose not to allow some types of cookies. Click on the different category headings to find out more and change our default settings. However, blocking some types of cookies may impact your experience of the site and the services we are able to offer. More information

Strictly Necessary Cookies
Always Enabled

These cookies are necessary for the website to function and cannot be switched off in our systems. You can set your browser to block or alert you about these cookies, but some parts of the site will not work as a result. These cookies are not used to market or advertise to site visitors.

Performance Cookies

These cookies allow us to count visits and traffic sources so we can measure and improve site performance. Information these cookies collect is anonymous. If you do not allow these cookies we will not know when you have visited our site, and will not be able to monitor its performance.

Functional Cookies

These cookies enable the website to provide enhanced functionality and personalization. They may be set by us or by third party providers whose services we have added to our pages. If you do not allow these cookies then some or all of these services may not function properly.

Targeting Cookies

These cookies may be set through our site by our advertising partners, or by social media services that we have added to the site to enable you to share our content with your friends and networks. These cookies have been disabled for visitors from certain geographies in compliance with local law.

  • English
  • German